possibility to continue a stopped profile. Stopping the system creates an
entirely new profile. All data displayed previously is not saved.
3.5 Full screen
When selecting the
radargram screen is expanded, so
that it is covering the full screen.
Pressing the knob again will show
the normal screen with the different
menus and the radargram.
3.6 Filter
When selecting you can, by turning the knob, apply various
levels of a background removal filter. The affect of the filters will be noticed
immediately. Adjust to create the clearest most interpretable image
possible. Going from zero to full filter setting has the effect of removing
progressively more background signatures by average value calculations.
The manages the contrast of the radargram screen. The turn-
push button is used to increase and decrease the contrast.
The allows gain adjustment of the radar data. Use the turn-push
button for increasing or decreasing the applied time gain. Gain is very
useful for making targets appear brighter in the radargram, this is especially
important when searching for deeper targets.
3.7 Save image (only for the IXM monitor)
With the IXM monitor it is possible to save measured radargram images
(what is seen on the screen).